Don't you want pores and easy pores and skin, that may be a trademark? The greater time of mobile formation at the surface of the pores and skin makes the pores and pores and pores and skin appear dry and dry. Every girl should have good, exquisite pores and pores and pores and skin, no question like celebrities that we normally recognize on TV in terms of mag covers and highlights. However, aside from the cash workers, to preserve to misuse huge names. For humans, regular humans begin with pores and well-handled pores and pores and skin, and a bit real electricity is needed to get smooth, foamy pores and pores and skin. The most component takes 3 months and half of to study the slope that measures heat affecting the pores and skin vertically.

 

https://www.facebook.com/ViaBeautySkinCream/
https://www.completefoods.co/diy/recipes/via-beauty-cream-reviews-must-read-before-buying-benefits-sideeffects
https://www.saatchiart.com/art/Photography-Via-Beauty-Cream-Reviews-Skin-Care-Anti-Aging/1465615/7168153/view


How can I get NiVisa100D.lib?

$
0
0

First,please  allow me to introduce myself,I am a Chinese,my English is very poor,sorry to make you laught at me.

 

When I debugged my C project,the VS2012 signaled an error as the follow figure.But there is not  NiVisa100D.lib In my computer.I need help.

 

 

2.png

Slimymed kapseln

How can I get NiVisa100D.lib?

$
0
0

First,please  allow me to introduce myself,I am a Chinese,my English is very poor,sorry to make you laught at me.

 

When I debugged my C project,the VS2012 signaled an error as the follow figure.But there is not  NiVisa100D.lib In my computer.I need help.

 

 

2.png

How to use LabVIEW to control Nikon A1R Ti2E microscope?

$
0
0

I wonder has anyone used LabVIEW to control Nikon A1R Ti2E microscope? Thanks a lot!

Digital port determine wether it is set to input or to output

$
0
0

Hi there I am new to NI,

 

I use the NI-USB-6001

I can setup the ports for input and output by using the examples in:

"...Documents\National Instruments\NI-DAQ\Examples\DAQmx ANSI C\Digital\Read Values"  

DAQmxErrChk(DAQmxCreateDOChan(taskHandle, "Dev1/port0/line1", "", DAQmx_Val_ChanPerLine));

 

 

But how do I retrieve the information if a port or port pin is setup as an input or an output port.

 

 

The storage could not be opened when using TDM C DLL for reading TDMS files

$
0
0

I try to read the TDMS files by my C++ code. Then I downloaded the package from the NI website“Use third-party software to read and write TDMS files”. I made some changes to the sample "readFile.c".  When I Compile successfully, and try to run the program. But a error as following occurred:

Error: The storage could not be opened.

 

Can anyone help me out. Many thanks.

NI4882

$
0
0

Where can I find an offline installer for NI4882?


Analog input using external trigger

$
0
0

Dear all

 

Hello, I have a problem to get analog input using external trigger.

I'm a newbie, so probably I missed very basic point.

Actually, I wanna do this job via python, but I came here cause there's no forum for python user. It shouldn't be very different from C++ I guess.

(Well, the question is not related to the measurement studio too..)

 

I have USB-6212 (windows10, python 3.7.6, NI MAX 18.5) and want to get analog signal, and am using sync signal(TTL) from a function generator as a trigger.

 

First, I created a task, then created AI voltage channel and set sample clock timing.

And then I connected BNC cable from function generator output to AI0, generated ~for example, sine wave(+-4V, 100Hz).

 

If I read the data without trigger, I can see the waveform generated by the function generator very well.

 

However, if I put

nidaq.DAQmxCfgDigEdgeStartTrig(AItaskHandle,b"Dev%d/PFI0"%num,DAQmx_Val_Rising)
(num is just a device # obtained using DAQmxSelfTestDevice, DAQmx_Val_Rising is 10280)
before the DAQmxStartTask,
I cannot see anything, even if I didn't changed anything of the analog input part.
I connected the TTL signal to PFI0. (I can see the TTL signal via analog input channel, I'm sure that the function generator works well. However, I couldn't see the signal via PFI0 channel. I tried to see it via PFI0 creating Digital input channel and read it, but it just gives me 0 all the time. I'm not sure this is a right way to check if PFI0 channel is alive or not.)
 
Do you have any idea what is the problem here?
Should I do something else or more to do the trigger?
or is there any possibility that PFI0 channel is broken?
 
Please let me know if you need any further information.
 
Thank you so much in advance.
 

LAVIEW 与MFC执行效率对比

$
0
0

今天在做效率对比时,发现LV的效率居然比MFC要快,我使用的是inter I5-7200U 8G内存,windows64位操作系统,LV安装的是LABVIEW 2016 32位,VS安装的是VS2015

测试算法为1亿次加法运算与一亿次除法运算。都使用for循环进行

 LV 耗时 100毫秒左右

VS耗时235毫秒左右

 

谁能告诉我是为什么吗/耗时100毫秒耗时100毫秒耗时235毫秒耗时235毫秒

谁能高数我为什么吗?难道是LV的执行效率比C++还高?

Error 1304 happened on Win7 x86 while installing the package made by NI Measurement Studio Installer Builder

$
0
0

Hi,

 

We made the Installer package with the help of NI Measurement Studio Installer Builder. The Installer ran properly on Win7 x64 without any issue. But when we ran the Installer package on Win7 x86, an Error 1304 would pop-up to block the installation.

Has anybody encountered similar issue before? How to solve this problem? Please. advise.

I have attached the Screenshot for this Error and also the log created during the installation and the Merge Modules I added in the Installer for your reference. Appreciate your attention and help in advance.

 

Thanks,

Kevin 

Lipo CLA

Error 1304 happened on Win7 x86 while installing the package made by NI Measurement Studio Installer Builder

$
0
0

Hi,

 

We made the Installer package with the help of NI Measurement Studio Installer Builder. The Installer ran properly on Win7 x64 without any issue. But when we ran the Installer package on Win7 x86, an Error 1304 would pop-up to block the installation.

Has anybody encountered similar issue before? How to solve this problem? Please. advise.

I have attached the Screenshot for this Error and also the log created during the installation and the Merge Modules I added in the Installer for your reference. Appreciate your attention and help in advance.

 

Thanks,

Kevin 

Primal Grow Pro

$
0
0

https dragonsdenketo com/primal-grow-pro/

Error 1304 happened on Win7 x86 while installing the package made by NI Measurement Studio Installer Builder

$
0
0

Hi,

 

We made the Installer package with the help of NI Measurement Studio Installer Builder. The Installer ran properly on Win7 x64 without any issue. But when we ran the Installer package on Win7 x86, an Error 1304 would pop-up to block the installation.

Has anybody encountered similar issue before? How to solve this problem? Please. advise.

I have attached the Screenshot for this Error and also the log created during the installation and the Merge Modules I added in the Installer for your reference. Appreciate your attention and help in advance.

 

Thanks,

Kevin 


How complete is VC++ concepts support in 16.3?

$
0
0

The latest VC++ Preview seems to support concepts without any special switch, though intellisense doesn't work. How complete is the concepts support? I tested a couple of simple concepts, and they seem to compile fine. But std::sort still barfs when given an incompatible type.

As a side note, the new semantic colorization scheme thinks = default is control flow.

Acquiring waveform using DSOZ204A, VC++ and Visa library ?

$
0
0

Hello everyone,

 

I'm actually trying to acquire a waveform of my infiniium DSOZ204A from Keysight.

I use the Visa Library 32bit and VC++ 2008 express edition.

I've copied, pasted and modified the code given by Keysight in their documentation. After a few bug correction the communication was established and I was able to modify some attributes.

But, when the acquiring process comes everything goes wrong. I send the command :WAVeform:DATA? to access the buffer where the data is and when it comes to the reading part I have an error : "VISA error: a format specifier in the format string is not valid". Then, a security implemented by Keysight in the code tell me that the IEEE block buffer is full.

Does anyone know where the problem is?

SyncPulse for cDAQ DSA modules

$
0
0

Hello!

 

My Hardware:

cDAQ-9188 Ethernet Chassis

2 pcs NI 9234 DSA modules

 

I've some troubles with synchronizing these two dsa modulkes when running at different sample rates. I've done synchronization with DAQmx functions and followed the steps from http://www.ni.com/tutorial/53867/en/

Unfortunately, it's written for Labview, not for text based programming. It's not possible (up to now) to use the SyncPulse with it's SyncPulseResetDelay property. I'm able to read the SyncPulseResetTime's for the two tasks (one with high, one with lower sample rate) and I'm able to set the SyncPulseResetDelay, but when starting the tasks, there seems to be no SyncPulse at all. Maybe I miss a DAQmx function for Release of the Pulse...

Here is what happens in my code:

 

- set up the two tasks with different sample rates

- use same SampClkTimebaseSrc and SampClkTimebaseRate for both modules

    - setting the DAQmxCfgSampClkTiming for Slave and Master

- then, read the SyncPulseResetTime from Slave and Master

- set the SyncPulseResetDelay of Slave and Master according to max(ResetTime's of all tasks) - SyncPulseResetTime of this task

- reserve master task (the one with slower sample rate) via DAQmxTaskControl(MasterTaskHandle,DAQmx_Val_Task_Reserve)

- read the SampClkTerm and SyncPulseTerm from reserved Master

- use SampClkTerm from Master to trigger the Slave with DAQmxCfgDigEdgeStartTrig(SlaveTaskHandle,...)

- use SyncPulseTerm from Master as SyncPulseSrc for the Slave

- DAQmxStartTask(SlaveTaskHandle) the Slave (waiting for trigger)

- DAQmxTaskControl(MasterTaskHandle,DAQmx_Val_Task_Commit) the Master

    - as I understood, with setting state of the Master to "commit", the Master releases a SyncPulse at the SyncPulseTerm and thus, the Slave should get the SyncPulse, because the Slave's SyncPulseSrc is connected to the Master's SyncPulseTerm. But unfortunately, there seem to be some problem. Is it possible, that the SyncPulse isn't recognized by the Slave, because the Slave is waiting for trigger? If so, how is it done? How do I control the release of the SyncPulse to be sent when both tasks are running?

- starting the continuous acquisition with DAQmxStartTask(MasterTaskHandle).

 

The trigger for the slave works fine, but not the SyncPulse. The next interesting thing is, that (of course, without the SyncPulse functionality), I get time delay between the two tasks (triggered start) of exactly 0.3*Delta of SyncPulseResetTime. This is very strange, but if I do the Signal Sync for the delay in postprocessing (because SyncPulseResetDelay does not work properly), the delay between the two signals is 0.3*DeltaSyncPulseResetTime.

 

I added two figures. One is the synced measurement data, when I subtract 0.3 times Delta in postprocessing. The other one is the corresponding Labview VI for this type of Sync. I marked a connection that could be some kind of SyncPulseLine I forgot in my code, so what is it? What's the corresponding DAQmx function for that Symbol?

 

Hope, you can help me,

Kind regards, BertramD

How to configure multiple AI channels scanning at differerent rates in Visual C++?

$
0
0

Hi,

is it possible to scan multiple AI channels

 

 

 at different sampling rates each of them?

If yes, I am intersted in knowing the DAQmx C++ function that should be used to configure the rates this way.

I am using NI USB 6000-6001-6002 series cards.

Thanks.

Migrating NI MS VS6 to latest [obsolescence management]?

$
0
0

One of my clients wants to update his existing MXI system based on Windows 7 to Windows 10 with new computer hardware.

The system is PXI connected over Fiber with MXI PCI card on a 3rd gen Intel Xeon based server. The software is written in VC++ 6 with I guess measurement studio 6.

According to my knowledge and internet, Measurement Studio VC++ 6.0 is not supported by windows 7 but my client has its working on Windows 7. Their OEM somehow Configured it to work with Windows 7.

 

What I am supposed to do is:

- Update their computer to newer 8th gen based system

- Update Windows 7 to windows 10.

- Since source code is available, make it run on latest Measurement Studio

- Newer computers usually do not have PCI slots, can I use PCIe to PCI converter and mount MXI on it?

 

How much of it is possible?

Viewing all 652 articles
Browse latest View live


<script src="https://jsc.adskeeper.com/r/s/rssing.com.1596347.js" async> </script>